Read and understand this manual and all instructions before operating the DR Dual-Action Electric Log Splitter.
`
Original Language
DR
®
DUAL-ACTION ELECTRIC LOG SPLITTER
SAFETY & OPERATING INSTRUCTIONS
Serial No.
Order No.
DR Power Equipment
Toll-free phone: 1-800-DR-OWNER (376-9637)
Fax: 1-802-877-1213
Website: www.DRpower.com
Vista de página 0
1 2 3 4 5 6 ... 35 36

Resumo do Conteúdo

Página 1 - Original Language

Read and understand this manual and all instructions before operating the DR Dual-Action Electric Log Splitter. `Original Language DR® DUAL-ACTION EL

Página 2 - Table of Contents

10 DR® DUAL-ACTION ELECTRIC LOG SPLITTER 6. Install the Castle Nut onto the Axle Threads with a 1-1/2" Wrench until the Tapered Bearing

Página 3

CONTACT US AT www.DRpower.com 11 Figure 16 Control Lever Jam Nut Flat Washer Note: Remove protective Caps as needed for the following Hydrau

Página 4 - Safety for Children and Pets

12 DR® DUAL-ACTION ELECTRIC LOG SPLITTER 29. Install the Trays onto the sides of the Beam assembly by aligning the legs with the receiving tub

Página 5 - General Safety

CONTACT US AT www.DRpower.com 13 Check the Tire Pressure Tools Needed:  Tire Pressure Gauge  Air Compressor 5. Remove the Valve Stem Pro

Página 6 - A Note to All Users

14 DR® DUAL-ACTION ELECTRIC LOG SPLITTER Chapter 3: Operating Your DR DUAL-ACTION ELECTRIC LOG SPLITTER It may be helpful to better familiariz

Página 7

CONTACT US AT www.DRpower.com 15 Hands on Sides of Wood Figure 26 Wood Against Stop Base Splitting Note: All logs should be no longer than 2

Página 8 - Specifications

16 DR® DUAL-ACTION ELECTRIC LOG SPLITTER 3. Hold the Valve Control Handle, moving the Wedge towards the Log until the log is split or the cy

Página 9 - Assembly

CONTACT US AT www.DRpower.com 17

Página 10

18 DR® DUAL-ACTION ELECTRIC LOG SPLITTER Chapter 4: Maintaining The DR DUAL-ACTION ELECTRIC LOG SPLITTER Regular maintenance is the way to ens

Página 11

CONTACT US AT www.DRpower.com 19 Hydraulic Fluid Change Tools and Supplies Needed:  Adjustable Wrench  Clean Rags  Approved Container (

Página 12 - Adding Hydraulic Fluid

2 DR® DUAL-ACTION ELECTRIC LOG SPLITTER This indicates a hazardous situation, which, if not avoided, could result in death or serious injury.

Página 13 - Check the Tire Pressure

20 DR® DUAL-ACTION ELECTRIC LOG SPLITTER Replacing the Wheels Tools and Supplies needed:  Channel lock Pliers  Clean Rags  Adjustable Wr

Página 14

CONTACT US AT www.DRpower.com 21 Adjusting the Pressure Valve The Log Splitter is set at the factory to optimize splitting force. The follow

Página 15 - Splitting

22 DR® DUAL-ACTION ELECTRIC LOG SPLITTER

Página 16 - Splitting Large Logs

CONTACT US AT www.DRpower.com 23 Chapter 5: Troubleshooting Most problems are easy to fix. Consult the Troubleshooting Table below for common

Página 17

24 DR® DUAL-ACTION ELECTRIC LOG SPLITTER Troubleshooting Table (Continued) SYMPTOM POSSIBLE CAUSE Ram advances with a jerky motion or with str

Página 18 - EACH USE

CONTACT US AT www.DRpower.com 25 Chapter 6: DR DUAL-ACTION ELECTRIC LOG SPLITTER Road Towable Kit Tools and Supplies Needed:  Two 7/16"

Página 19 - Hydraulic Fluid Change

26 DR® DUAL-ACTION ELECTRIC LOG SPLITTER 18. Assemble the Fenders to the Frame with eight 5/16-18 x 3/4" Carriage Bolts (fender side) and

Página 20 - Replacing the Wheels

CONTACT US AT www.DRpower.com 27 Figure 45 Lock Nut Ball Clamp Spring Figure 44 Pull Locking Trigger 1/16" Movement Attaching to Tow Veh

Página 21 - Adjusting the Pressure Valve

28 DR® DUAL-ACTION ELECTRIC LOG SPLITTER Chapter 7: Parts Lists, Schematic Diagrams And Warranty Parts List - FRAME ASSEMBLY NOTE: Part number

Página 22 - 22 DR

CONTACT US AT www.DRpower.com 29 Schematic – FRAME ASSEMBLY

Página 23 - Troubleshooting Table

CONTACT US AT www.DRpower.com 3 Read this safety & operating Instructions manual before you use the DR DUAL-ACTION ELECTRIC LOG SPLITTER

Página 24 - SYMPTOM POSSIBLE CAUSE

30 DR® DUAL-ACTION ELECTRIC LOG SPLITTER Parts List – BEAM ASSEMBLY NOTE: Part numbers listed are available through DR Power Equipment. Ref#

Página 25

CONTACT US AT www.DRpower.com 31 Schematic – BEAM ASSEMBLY

Página 26

32 DR® DUAL-ACTION ELECTRIC LOG SPLITTER Parts List – MOTOR AND PUMP ASSEMBLY NOTE: Part numbers listed are available through DR Power Equipme

Página 27 - Hitch Coupler Adjustment

CONTACT US AT www.DRpower.com 33 Schematic – MOTOR AND PUMP ASSEMBLY

Página 28 - Parts List - FRAME ASSEMBLY

34 DR® DUAL-ACTION ELECTRIC LOG SPLITTER Parts List – ROAD-TOW ACCESSORY NOTE: Part numbers listed are available through DR Power Equipment.

Página 29 - Schematic – FRAME ASSEMBLY

CONTACT US AT www.DRpower.com 35 Schematic – ROAD TOW ACCESSORY

Página 30 - Parts List – BEAM ASSEMBLY

75 MEIGS ROAD, P.O. BOX 25, VERGENNES, VERMONT 05491 ©2013 Country Home Products, Inc. All rights reserved 276151A Daily Checklist for the DR DUAL-A

Página 31 - Schematic – BEAM ASSEMBLY

4 DR® DUAL-ACTION ELECTRIC LOG SPLITTER High fluid pressures are developed in hydraulic machines. Pressurized hydraulic fluid escaping throug

Página 32 - 32 DR

CONTACT US AT www.DRpower.com 5 Never overlook the hazards of electricity. Always follow these precautions:  Never open the switch box or

Página 33

6 DR® DUAL-ACTION ELECTRIC LOG SPLITTER A Note to All Users No list of warnings and cautions can be all-inclusive. If situations occur that

Página 34 - 34 DR

CONTACT US AT www.DRpower.com 7 Figure 1 Jack Pneumatic Tires Operator Lever Chapter 2: Setting Up The DR DUAL-ACTION ELECTRIC LOG SPLITTER

Página 35

8 DR® DUAL-ACTION ELECTRIC LOG SPLITTER Specifications Motor 1.8kW, 110V AC Motor Bed height 24" (610mm) Wedge 6.61" (168mm) h, .7

Página 36 - End of Season and Storage

CONTACT US AT www.DRpower.com 9 1. Open the Parts Box and lay them out on a clean flat area (Figure 2). Note: For assembly location, the pa